Bang & Olufsen ML Gateway Guide d'installation Page 46

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 58
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 45
Supported devices 46
Vantage
Connection to a Vantage system
Communication with a Vantage system is done through an InFusion Dim Controller. This device has both RS232 and Ethernet interfaces.
Connection to the RS232 interface can be done directly using a fully wired RS232 cable and it is xed at no parity, 1 stop bit, 8 data bits. Make
sure to congure bit rate and ow control as needed. Connection settings for Ethernet are the IP address of the InFusion Dim Controller and its
telnet port.
Dening Vantage resources
To program the InFusion Dim Controller, the PC tool Design Center is needed. It lets you dene all components of your Vantage system, where
each one has an address called VID (Vantage Identication Number).
On MLGW you can dene as resources either a button on any control, or a task. To dene a resource, you need to know the Button or Task vid,
wich must be entered in the ID eld.
Vantage events and commands
An event corresponds to a Button press or release, or a Task activation or deactivation. Supported commands are Button press and release,
Button press, Button release and Task activation.
Vue de la page 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 57 58

Commentaires sur ces manuels

Pas de commentaire